ESB Networks Sagemcom XS211 smart meter with its P1 port connected to a Smart Gateways Smart Meter WiFi Gateway ESPHome Edition, with the Home Assistant Energy dashboard and ESPHome logo in the background
An ESB Networks (Sagemcom XS211) smart meter feeding live P1 data into the Home Assistant Energy dashboard via the Smart Gateways Smart Meter WiFi Gateway ESPHome Edition.

Disclosure: HAProfs.com is run by Smart Gateways, the Dutch company that makes the gateway described here. The Irish setup, the telegram analysis and the ESPHome configuration in this article come from James Pelow, an ESB Networks customer in Ireland who got it working in the first week after launch and shared his work so others could use it. His findings and our side of the support exchange are reproduced with his permission. Where it says “we”, that’s Smart Gateways; where it says “James”, that’s the customer who did the real work.

In short: In November 2026, ESB Networks (ESBN) enabled the P1 port on Irish smart meters nationwide. If your meter has the port, you switch it on yourself in your ESB Networks online account (takes up to an hour), plug in the Smart Gateways Smart Meter WiFi Gateway ESPHome Edition, and get live import, export, three tariff registers and voltage events straight into Home Assistant. Fully local, no cloud, no power adapter (the meter powers the gateway), and because it runs ESPHome you can fine-tune every sensor yourself. The Irish ESPHome configuration is included below. If your meter has no P1 port, ask ESB Networks for a free replacement (1800 928 123).

Background: Smart Meters in Ireland and the ESB Networks Rollout

Ireland’s National Smart Metering Programme started installing meters in 2021 under ESB Networks, the state-owned distribution system operator. By now the vast majority of homes and businesses have been converted, roughly 2.4 million meters in total. Installation was free, took under an hour, and the programme’s cost is recovered through network charges on everyone’s bill.

A few facts that matter for what follows:

  • The meter reports 30-minute interval data back to ESB Networks over the mobile network. Your supplier (Electric Ireland, Energia, Bord Gáis, SSE Airtricity, Pinergy and so on) gets that data from ESB Networks for billing.
  • That data enables smart / time-of-use tariffs with separate day, night and peak rates. A smart meter on its own doesn’t lower your bill; a smart tariff you use well might.
  • Opting out of the rollout was possible, which is why some homes still have older meters.
  • Until now, the only ways to see your own usage were the ESB Networks portal, your supplier’s app, the meter’s LCD or its flashing kWh LED. All of them either delayed, coarse or import-only.

That last point is the gap the P1 port fills.

What Is the P1 Port (HAN Port) on an ESB Networks Meter?

The P1 port, which ESB Networks also calls the HAN port (Home Area Network), is a small RJ12 socket on the meter, usually behind a cover on the underside or front. It’s the same interface used on Dutch and Belgian smart meters under the DSMR standard, which is why a reader built for that market works here.

When enabled, the meter pushes a plain-text telegram out of this socket roughly once per second: current power in and out, cumulative energy per tariff, reactive power, current, voltage sags and swells, power failures, meter clock. Each telegram ends with a CRC16 checksum so a reader can verify it.

PropertyESB Networks P1 port
ConnectorRJ12 (6P6C)
ProtocolDSMR 5-style P1 telegram
Header/ESB5\…
Baud rate115200, 8N1
Power to the reader5 V supplied by the meter
ChecksumCRC16
DataElectricity only (no gas/water channels)
Import tariffsThree (1.8.1, 1.8.2, 1.8.3)
EnablementRemote, by the customer, via ESB Networks online account

ESB Networks explicitly states it does not supply in-home display devices (you can see that on the portal screenshot in Step 2). The port is there for whatever you plug in yourself.

Why This Matters for Home Assistant Users in Ireland

The P1 port is the best possible data source for a Home Assistant Energy dashboard:

  • Local. Nothing leaves your house. No mobile signal, no cloud account, no supplier API that breaks every six months.
  • Real time. One reading per second instead of 30-minute blocks published hours later.
  • The meter’s own registers. Not a CT clamp approximation. The same numbers ESB Networks bills from.
  • Export included. With solar, you see what you push to the grid, which the meter’s LED can’t show.
  • Tariff-aware. The three tariff registers map directly onto day/night/peak smart plans.

The news broke on r/ireland and r/homeassistant in early November 2026 and Irish orders for P1 readers, ours included, went through the roof within hours. It also became clear very quickly that a lot of Irish meters don’t have the port, which is why compatibility gets its own section below.

The Smart Meter WiFi Gateway ESPHome Edition: Why It Fits Ireland

We sell two versions of our P1 reader: the standard Smart Meter WiFi Gateway with our own firmware which is not ready for Ireland, and built-in meter profiles, and the Smart Meter WiFi Gateway ESPHome Edition, same hardware, running open-source ESPHome. For Ireland right now, we’ll be straight with you: get the ESPHome Edition. Here’s why.

  • Powered by the meter. The P1 port supplies 5 V and the gateway runs on that alone. No power adapter, no socket needed in the meter cabinet, no extra cable. You plug it in and it’s alive.
  • Runs ESPHome. This is the big one. The gateway is an ESP32 running the open-source ESPHome firmware, which means the entire configuration is a YAML file you control. Every sensor, every name, every unit, every calculation. When Ireland switched on a P1 port with a telegram format nobody had seen before, James had the ESPHome Edition adapted in an afternoon. Our standard firmware doesn’t have an Irish profile yet; a closed-firmware dongle from anyone would still be waiting on its vendor.
  • USB-C Port for flashing the firmware and additional power if the meter does not supply enough
  • 15cm P1 cable with RJ12 connectors on both sides
  • Native Home Assistant integration. ESPHome devices are discovered automatically by Home Assistant over the encrypted native API. No MQTT broker, no extra integration, no polling.
  • Over-the-air updates. Once flashed, you tweak the YAML and push updates over Wi-Fi from the ESPHome add-on. You never touch the meter cabinet again.
  • Built-in web server and fallback access point. If Wi-Fi drops, the gateway opens its own hotspot so you can reconfigure it. The web server lets you check sensor values from any browser.
  • Tidy hardware. A small box with an RJ12 cable and a status LED. No soldering, no breadboard, and included 3D-printed case.
3D render of the SmartGateways.nl Smart Meter Gateway ESPHome Edition in a blue enclosure, showing the RJ12 P1 port and micro-USB power connector
The SmartGateways.nl Smart Meter Gateway (ESPHome Edition) with RJ12 P1 port and USB-C power – plug-and-play for ESB Networks smart meters in Ireland.

James ran it on an ESB Networks single-phase smart meter (Sagemcom XS211) with Home Assistant and the ESPHome add-on. He captured byte-exact telegrams, mapped every OBIS code ESB uses, adapted our ESPHome config and sent it back so other Irish customers could benefit. This guide is built on that work.

Compatibility: Which ESB Networks Meters Work and Which Don’t

Meters That Work

  • ESB Networks smart meters with a physical P1/HAN RJ12 socket. The single-phase Sagemcom XS211 used here is one.
  • The port must be enabled by you in your ESB Networks account. It’s off by default.
  • These meters send clean DSMR 5-style telegrams (/ESB5\…, CRC OK).

Meters That Don’t Work (Yet)

  • Earlier-generation smart meters without a P1 socket. A significant share of the rollout used these. There’s physically nothing to plug into.
  • Meters the portal refuses to enable. When you open Manage My P1 Port for such a meter, ESB Networks shows the message below. Many Irish users reported exactly this in the first days after launch, including a second Irish customer of ours who found out after ordering (we refunded him, and we’d rather you didn’t have to go through that). Check your portal before you buy hardware.
  • Three-phase meters: untested. The config below is single-phase tested; three-phase users will likely need to add L2/L3 sensors, which ESPHome makes easy.

“Functionality Unavailable – The smart meter model installed at your property cannot be enabled to allow a connection to a P1 port via your online account.”

Compatibility Table

Your situationWorks?How to checkWhat to do
Meter has RJ12 socket, port enabled✅ YesPortal shows green “Your P1 Port is currently enabled”Flash the ESPHome config (Step 4)
Meter has RJ12 socket, port not yet enabled⚠️ Not until enabledPortal shows “Enable my P1 Port” buttonEnable it (Step 2), wait up to an hour
Meter has no RJ12 socket❌ NoPortal shows “Functionality Unavailable”Request replacement (below)
Three-phase meter with P1 socket❓ UntestedPortal as aboveTry the config; add L2/L3 sensors
Old non-smart meter (opted out)❌ NoNo smart meter at allContact ESB Networks for a smart meter

Getting a Meter Without a P1 Port Replaced

ESB Networks runs a cyclical meter replacement programme to swap smart meters that lack a P1 port: esbnetworks.ie/services/manage-my-meter/cyclical-meter-replacement. You can reportedly ask to be moved up the queue by phoning 1800 928 123. The replacement is free, takes under an hour, and your power is off briefly. Once the new meter is in, go to Step 2.

Step 1: Check Whether Your Meter Can Be Enabled

Do this before ordering anything.

  1. Register or log in at www.esbnetworks.ie. You’ll need your MPRN, printed on any electricity bill.
  2. Go to Access Additional Data Services → Manage My P1 Port. Direct link: myaccount.esbnetworks.ie/energymanagement/additional-data-services.
  3. If you see an Enable my P1 Port button, you’re good. If you see Functionality Unavailable, your meter needs replacing first.

You can also look for the small RJ12 socket (like a narrow phone jack) under a cover on the meter.

Step 2: Enable the P1 Port in Your ESB Networks Account

Enablement is remote. No engineer visit.

1. Log in at www.esbnetworks.ie.

2. Open Access Additional Data Services.

Step 2: on your ESB Networks account page, open the “Access additional data services” tile.

3. Choose Manage My P1 Port.

Step 3: choose “Manage my P1 Port”. Enablement is fully remote; no engineer visit.

4. Click Enable my P1 Port. The portal confirms “You have successfully submitted a request to enable your P1 Port” and notes the update can take up to an hour. Refresh later to see the status change.

5. Done when you see the green tick:

Step 5: the green tick confirms the port is live. ESB Networks does not supply in-home displays; the gateway and Home Assistant take that role.

If you get “Something has gone wrong”: log out, log back in, try again. That fixed it for several people on launch day.

Step 3: Connect the Gateway

  1. Plug the RJ12 cable of the Smart Meter WiFi Gateway ESPHome Edition into the meter’s P1 socket. The port supplies 5 V, so there is no power adapter to find a socket for. This alone makes it the easiest install in the smart home.
  2. Keep the gateway at the meter. The P1 signal and supply are low-voltage; don’t try to run a long extension from the socket. Let the gateway do the distance over Wi-Fi.
  3. Irish meter cabinets are often outside or by the front door; check Wi-Fi reaches there. The gateway’s Wi-Fi signal sensor (in the config) tells you how it’s doing.
  4. First boot: the gateway opens its own access point (ESB Meter P1 Port Fallback with the config below). Connect, enter your Wi-Fi details, done.

One socket, one device. The meter has a single P1 port and it can only power one reader. If you later want a second device on it (a home battery or inverter that reads the P1 port, or a second gateway for a separate system), you need a splitter that provides its own power. Our Active P1 Splitter Pro exists for exactly that; it’s the answer to a question that comes up in every P1 thread, Irish or Dutch.

A note on the stock profiles: our standard firmware ships with meter profiles for the Netherlands, Belgium, Sweden, Hungary and Lithuania. None of those parses the Irish telegram yet (every telegram shows as an error), because Ireland only switched the port on days ago and the Irish format has features like three import tariffs that the Dutch profile doesn’t expect. An Irish profile is on our list, but that’s precisely why the ESPHome Edition is the right choice today: you don’t wait for a profile, you load one. Which brings us to Step 4.

Step 4: Flash the Irish ESPHome Configuration

Prerequisites

  • ESPHome add-on in Home Assistant.
  • Add wifi_ssid, wifi_password, api_encryption_key, ota_password and ap_password to ESPHome’s secrets.yaml.
  • First flash over USB-C (ESPHome web flasher or the add-on). Every update after that goes over the air.

Register codes are kept in the sensor names (e.g. “1.8.1”) so you can cross-check them against what scrolls on the meter’s display.

# ESPHome config for the Smart Gateways Smart Meter WiFi Gateway ESPHome  
# Edition on an ESB Networks (Ireland) smart meter.  
#  
# Adapted for ESB Networks (Ireland) by James Pelow, November 2026, from  
# Smart Gateways' own ESPHome config (2025-10-21). The Dutch-only sensors are  
# removed and the registers sent by ESB meters are added. Tested on a  
# single-phase ESB (Sagemcom XS211) meter.  
#  
# Before flashing, add these to your ESPHome secrets:  
#   wifi_ssid, wifi_password, api_encryption_key, ota_password, ap_password  
#  
# The register codes (1.8.0 etc.) are in the sensor names so they can be  
# matched against the codes shown on the meter's display.  
#  
# ESB quirk (Nov 2026): 1-0:1.8.0 and 1-0:2.8.0 only carry the last 4 digits  
# before the decimal point (e.g. 1897.040 instead of 31897.040). "Energy  
# Consumed Tariffs Total" adds up the three tariff registers, which are sent in  
# full, so it stays correct either way. The meter sends no export tariff  
# registers, so the export total can't be rebuilt the same way. This has been  
# reported to ESB Networks as a bug.  
#  
# In the Home Assistant Energy dashboard, use "Energy Consumed Tariffs Total"  
# for grid import and "Energy Produced Total" for export (the dashboard only  
# uses the change between readings, so the truncation doesn't matter).  
esphome:  
  name: esb-meter-p1-port  
  friendly_name: ESB Meter P1 Port  
  comment: Smart Gateways Smart Meter WiFi Gateway ESPHome Edition on ESB smart meter  
esp32:
  board: esp32dev
  cpu_frequency: 240MHz
  framework:
    type: arduino
    advanced:
      minimum_chip_revision: "3.1"
      sram1_as_iram: true
preferences:  
  flash_write_interval: 1min  
improv_serial:  
logger:  
  baud_rate: 115200  
  level: INFO  
debug:  
  update_interval: 60s  
api:  
  encryption:  
    key: !secret api_encryption_key  
ota:  
  - platform: esphome  
    password: !secret ota_password  
wifi:  
  ssid: !secret wifi_ssid  
  password: !secret wifi_password  
  power_save_mode: none  
  ap:  
    ssid: "ESB Meter P1 Port Fallback"  
    password: !secret ap_password  
captive_portal:  
web_server:  
  port: 80  
time:  
  - platform: sntp  
    id: time_now  
uart:  
  baud_rate: 115200  
  rx_pin:  
    number: GPIO18  
    inverted: true  
  rx_buffer_size: 3000  
  data_bits: 8  
  parity: NONE  
  stop_bits: 1  
dsmr:  
  id: dsmr_instance  
  max_telegram_length: 3000  
  receive_timeout: 500ms  
output:  
  - platform: gpio  
    id: led_wifi_connected  
    pin: 2  
interval:  
  - interval: 2s  
    then:  
      if:  
        condition:  
          wifi.connected:  
        then:  
          - if:  
              condition:  
                api.connected:  
              then:  
                - output.turn_on: led_wifi_connected  
                - delay: 200ms  
                - output.turn_off: led_wifi_connected  
                - delay: 200ms  
              else:  
                - output.turn_on: led_wifi_connected  
                - delay: 500ms  
                - output.turn_off: led_wifi_connected  
                - delay: 500ms  
        else:  
          - output.turn_off: led_wifi_connected  
sensor:  
  - platform: dsmr  
    # Import by tariff register (sent in full)  
    energy_delivered_tariff1:  
      name: "Energy Consumed Tariff 1 (1.8.1)"  
      id: energy_t1  
    energy_delivered_tariff2:  
      name: "Energy Consumed Tariff 2 (1.8.2)"  
      id: energy_t2  
    energy_delivered_tariff3:  
      name: "Energy Consumed Tariff 3 (1.8.3)"  
      id: energy_t3  
    # 1-0:1.8.0 / 2.8.0 (see ESB quirk above)  
    energy_delivered_lux:  
      name: "Energy Consumed Total (1.8.0)"  
      id: energy_consumed_total  
    energy_returned_lux:  
      name: "Energy Produced Total (2.8.0)"  
      id: energy_produced_total  
    # 1-0:3.8.0 / 4.8.0, reactive energy  
    total_imported_energy:  
      name: "Reactive Energy Imported (3.8.0)"  
    total_exported_energy:  
      name: "Reactive Energy Exported (4.8.0)"  
    power_delivered:  
      name: "Power Consumed (1.7.0)"  
      accuracy_decimals: 3  
    power_returned:  
      name: "Power Produced (2.7.0)"  
      accuracy_decimals: 3  
    reactive_power_delivered:  
      name: "Reactive Power Imported (3.7.0)"  
      accuracy_decimals: 3  
    reactive_power_returned:  
      name: "Reactive Power Exported (4.7.0)"  
      accuracy_decimals: 3  
    current_l1:  
      name: "Current (31.7.0)"  
    electricity_failures:  
      name: "Power Failures (96.7.21)"  
      icon: mdi:alert  
    electricity_sags_l1:  
      name: "Voltage Sags (32.32.0)"  
      icon: mdi:arrow-down-bold  
    electricity_swells_l1:  
      name: "Voltage Swells (32.36.0)"  
      icon: mdi:arrow-up-bold  
  - platform: template  
    name: "Energy Consumed Tariffs Total (computed)"  
    id: energy_consumed_tariffs_total  
    unit_of_measurement: kWh  
    device_class: energy  
    state_class: total_increasing  
    accuracy_decimals: 3  
    update_interval: 10s  
    lambda: |-  
      if (isnan(id(energy_t1).state) || isnan(id(energy_t2).state) || isnan(id(energy_t3).state))  
        return {};  
      return id(energy_t1).state + id(energy_t2).state + id(energy_t3).state;  
  - platform: uptime  
    name: "Uptime"  
  - platform: wifi_signal  
    name: "Wi-Fi Signal"  
    update_interval: 60s  
text_sensor:  
  - platform: dsmr  
    identification:  
      name: "Meter Identification"  
    timestamp:  
      name: "Meter Clock (1.0.0)"  
    electricity_switch_position:  
      name: "Supply Switch (96.3.10)"  
  - platform: wifi_info  
    ip_address:  
      name: "IP Address"  
  - platform: version  
    name: "ESPHome Version"  
  - platform: debug  
    reset_reason:  
      name: "Reset Reason"  
button:  
  - platform: restart  
    name: "Restart"  
    entity_category: diagnostic

After flashing, Home Assistant discovers the device through the ESPHome integration automatically. You don’t need the “P1 Monitor” or “DSMR” integrations.

Irish Telegram Quirks and OBIS Reference

What makes ESB Networks telegrams different from a Dutch or Belgian meter, and how the config handles it:

QuirkDetailHandling in config
Three import tariffs1.8.1, 1.8.2, 1.8.3 (day / night / peak). Dutch firmware expects two.All three exposed as separate sensors
Truncated totals1.8.0 and 2.8.0 carry only the last 4 digits before the decimal point (1897.040 instead of 31897.040). Reported to ESB Networks as a bug.Import total is rebuilt as the sum of the three tariff registers. Export can’t be rebuilt (no export tariff registers), but the Energy dashboard only uses deltas, so it doesn’t matter.
Reactive registers3.8.0 / 4.8.0 and 3.7.0 / 4.7.0 are sent.Exposed; handy for power-factor analysis
Electricity onlyNo gas or water channels.Dutch gas/water sensors removed
Header/ESB5\…Standard DSMR parser handles it

OBIS codes sent by ESB Networks meters (single-phase)

OBISMeaningHA sensor name
0-0:1.0.0Meter clockMeter Clock (1.0.0)
1-0:1.8.0Total energy imported (truncated)Energy Consumed Total (1.8.0)
1-0:1.8.1 / 1.8.2 / 1.8.3Imported energy, tariff 1 / 2 / 3Energy Consumed Tariff 1/2/3
1-0:2.8.0Total energy exported (truncated)Energy Produced Total (2.8.0)
1-0:3.8.0 / 4.8.0Reactive energy imported / exportedReactive Energy Imported / Exported
1-0:1.7.0 / 2.7.0Instantaneous power imported / exported (kW)Power Consumed / Power Produced
1-0:3.7.0 / 4.7.0Instantaneous reactive power imported / exportedReactive Power Imported / Exported
1-0:31.7.0Current L1 (A)Current (31.7.0)
0-0:96.7.21Number of power failuresPower Failures
1-0:32.32.0 / 32.36.0Voltage sags / swells L1Voltage Sags / Swells
0-0:96.3.10Supply switch positionSupply Switch

Step 5: Home Assistant Energy Dashboard and Time-of-Use Tariffs

In Settings → Dashboards → Energy:

  • Grid consumption: Energy Consumed Tariffs Total (computed)
  • Return to grid: Energy Produced Total (2.8.0)

Both are total_increasing, so long-term statistics work out of the box.

On a smart / time-of-use tariff? Use the three individual tariff sensors to track day, night and peak separately. Combined with the Utility Meter helper you can build per-rate cost tracking, which is where the real insight into an Irish smart plan comes from. The P1 port works regardless of your tariff; the registers are always there.

Beyond Electricity: Gas, Water and Heat on the Same Dashboard

One thing that surprises Dutch readers: the Irish telegram carries electricity only. In the Netherlands the gas meter is wired into the electricity meter and shows up in the same P1 telegram; in Ireland there’s no such channel, and water meters aren’t connected anywhere. So once the electricity half of the Energy dashboard is live, the gas and water tiles stay empty unless you do something about it.

These are the pieces we make for the rest of the picture, all with the same local-only, no-cloud approach:

  • Water. The Water Meter Gateway clips onto an analog water meter, reads the spinning dial optically, needs no plumbing, and feeds the Energy dashboard’s water tile. Its leak detection is the feature customers write to us about most.
  • Gas. Irish gas meters (Gas Networks Ireland) aren’t smart and have no data output. The Gas Meter Gateway works on the same principle as the water version: it reads the mechanical counter and reports m³ to Home Assistant. If you’re on gas heating, this is the missing piece for a complete Energy dashboard.
  • District heating or a digital water meter. Apartment blocks with heat meters, or homes with a Kamstrup MULTICAL or flowIQ meter, can use the Kamstrup Gateway, which reads the meter’s optical interface directly.
  • Tanks and levels. Not an energy thing, but for a rainwater tank, oil tank or well, the Water Level Gateway measures the surface distance and turns it into a level sensor. Oil-fired heating is still common in rural Ireland, so it’s worth knowing this exists.

None of this is required to get the P1 port working, and you can add it piece by piece. We mention it because “and how do I get gas and water in there too?” comes up in every Irish Home Assistant thread.

Fine-Tuning: Making the Gateway Your Own

This is where the ESPHome Edition earns its keep. Everything is in one YAML file, and a few lines change what the gateway does. Some ideas, all standard ESPHome patterns:

  • Rename sensors to match your supplier’s tariff names (“Day”, “Night”, “Peak”) instead of “Tariff 1/2/3”.
  • Add a cost sensor on the device itself with a template that multiplies each tariff delta by your unit rate.
  • Add a “currently exporting” binary sensor that flips when power_returned is above zero, for automations like “start the dishwasher when solar is spilling to the grid”.
  • Change the update interval of the computed total, or add filters: (e.g. throttle_average) to smooth the power readings if your graphs are jittery.
  • Three-phase? Add current_l2, current_l3, electricity_sags_l2/l3 and electricity_swells_l2/l3 under the dsmr sensor block. Five minutes.
  • Drop what you don’t need. Not interested in reactive power? Delete four lines.
  • Use the on-board LED for something useful: the config already blinks it for Wi-Fi/API status; you can repurpose it to flash on high import.
  • Push an update over the air from the ESPHome add-on. No trip to the meter cabinet, ever.

And if ESB Networks fixes the truncated 1.8.0 bug, or adds export tariff registers, you adapt the config the same afternoon rather than waiting on a firmware release, ours included.

Optional: Reduce Power Consumption on a Weak P1 Port

Most gateways run normally on power from the meter’s P1 port, and no changes are usually needed. In rare cases, a gateway may not start fully or may occasionally switch off. This is a known issue that can occur with some smart meters; it may appear suddenly and then go away again. The exact cause isn’t clear. Possible contributing factors include variations in the power supply, humidity, electrical load, or the temperature of the meter or its surroundings.

If you experience this, the following settings may help. One customer reported that lowering the ESP32’s CPU frequency from the default 240 MHz to 80 MHz, and adjusting the Wi-Fi settings, allowed the gateway to run reliably from the P1 port:

esp32:
  board: esp32dev
  cpu_frequency: 80MHz
  framework:
    type: esp-idf
    advanced:
      sram1_as_iram: true
      flash_chip: generic
      minimum_chip_revision: "3.1"
wifi:
  ssid: !secret wifi_ssid
  password: !secret wifi_password
  power_save_mode: HIGH
  output_power: 10.0

A lower CPU frequency can reduce the processor’s power consumption. power_save_mode: HIGH lets the Wi-Fi radio spend more time in a low-power state between communications, while output_power: 10.0 reduces the strength of its transmissions.

These settings don’t affect the meter readings or the gateway’s ability to process them. In a typical installation, the Wi-Fi connection and coverage should still be perfectly adequate. As with any Wi-Fi device, coverage depends on the distance and obstacles between the gateway and your router; if the signal is already weak, check that the connection remains stable after lowering the transmit power.

You probably won’t need to change anything. If you do experience power-related issues, use these settings as a starting point and test the gateway in your installation. They may help in these uncommon cases, and you can adjust them to find what works best for your setup.

How the First Irish Week Went: The Support Story

We think a guide like this should say what happened when things didn’t work, so here is our side of it, with James’s permission.

On a Monday afternoon in early November, a message came in through our contact form: an Irish customer’s new gateway was throwing an error on every telegram. We hadn’t seen an ESB telegram before, Ireland wasn’t a market we’d planned for, and we had no Irish profile. The next morning we replied with exactly that, and attached our ESPHome configuration so he could adapt it himself rather than wait for us.

A few hours later James sent back a working Irish YAML, with byte-exact telegram captures, every OBIS code mapped and the 1.8.0 truncation bug documented. That’s the configuration in Step 4. The following day a second Irish customer wrote in: his meter turned out to have no P1 port at all. We refunded him, put the two in touch, and added the “check your portal first” warning that now sits at the top of this article.

We’re telling this story for two reasons. First, so you know what to expect from us if you hit something new: an honest answer, quickly, and the source code if that helps. Second, because this whole guide exists thanks to one customer who did the hard work and shared it. If you get the config running on a three-phase meter or a different model, do the same and we’ll add it here with credit.

Troubleshooting

SymptomLikely causeFix
Portal says Functionality UnavailableMeter has no P1 portRequest replacement, 1800 928 123
Portal says Something has gone wrongSession glitchLog out and in again
Enabled, but nothing comes out of the portStill processingWait up to an hour, refresh status
Gateway LED on, stock firmware shows 100 % telegram errorsNo Irish profile yetFlash the ESPHome config (Step 4)
ESPHome shows CRC errorsUART settings or cableCheck inverted: true, 115200 8N1, RJ12 fully seated
1.8.0 doesn’t match meter displayKnown ESB truncation bugUse Energy Consumed Tariffs Total
Weak Wi-Fi at outdoor cabinetDistance / metal cabinetMove the access point or add a mesh node; don’t extend the P1 cable
Gateway reboots when a second device is plugged inP1 port can’t power two readersUse an Active P1 Splitter Pro with its own power supply
Three-phase meter, missing L2/L3Config is single-phaseAdd L2/L3 sensors (see Fine-Tuning)

Technical Specifications

ItemValue
GatewaySmart Gateways Smart Meter WiFi Gateway ESPHome Edition, ESP32 (esp32dev), Wi-Fi
PowerFrom the meter’s P1 port, 5 V; no adapter
ConnectorRJ12
UART115200 baud, 8N1, RX GPIO18 inverted
TelegramDSMR 5-style, /ESB5\…, CRC16, up to 3000 bytes
Update rate~1 telegram/s
FirmwareESPHome (config above), OTA updates
HA integrationESPHome native API, encrypted, auto-discovered
ExtrasBuilt-in web server, fallback access point, status LED
Tested meterESB Networks single-phase Sagemcom XS211, Ireland, November 2026

Verdict

It’s our product, so take the ratings as a summary of what works and what doesn’t yet rather than an independent review. Judge it by James’s result and your own.

  • Hardware: plug and go. Powered by the meter, no adapter, no soldering, no cloud.
  • Flexibility: the reason to pick this edition. Ireland’s unexpected telegram format was handled by a customer in one afternoon, without waiting for us.
  • Out-of-the-box Irish profile: not yet. You flash the config above. Ten minutes if you already use ESPHome, a modest learning curve if not, and this guide walks you through it. An Irish profile for the standard firmware is on our list.
  • Biggest risk: your meter. Not the gateway. Check the portal first.

Bottom line: if your ESB Networks meter has a P1 port, the Smart Meter WiFi Gateway ESPHome Edition with the config above gets live, local electricity data into Home Assistant today. If it doesn’t, phone ESB Networks about a replacement first.

Frequently Asked Questions (FAQ)

Does every Irish smart meter have a P1 port?
No. Many earlier ESB Networks meters have no P1 socket and the portal shows “Functionality Unavailable”. ESB Networks’ cyclical meter replacement programme swaps them free of charge; phone 1800 928 123.

How do I enable the P1 port on an ESB Networks meter?
Log in at esbnetworks.ie → Access Additional Data Services → Manage My P1 Port → Enable my P1 Port. It’s remote and takes up to an hour.

Does the Smart Gateways gateway work with Irish ESB Networks meters?
Yes, the ESPHome Edition does, with the configuration in this article. The stock meter profiles (NL, BE, SE, HU, LT) in the standard firmware don’t parse Irish telegrams yet.

Does the gateway need a power supply?
No. The P1 port supplies 5 V and the gateway runs on that. Keep it at the meter rather than extending the cable.

Can I connect two devices to the P1 port?
Not directly; the port powers one reader. An Active P1 Splitter Pro with its own power supply lets you run the gateway alongside, for example, a battery or inverter that also reads the P1 port.

Which protocol does the ESB Networks P1 port use?
DSMR 5-style P1 telegrams at 115200 baud, header /ESB5\…, CRC16. Electricity only, three import tariff registers.

Does the P1 port work if I export solar?
Yes. Telegrams include export power (2.7.0) and export energy (2.8.0), unlike the meter’s LED, which only shows import.

Why doesn’t my 1.8.0 total match the meter display?
ESB meters currently truncate 1.8.0 and 2.8.0 to four digits before the decimal point. Use the computed “Energy Consumed Tariffs Total” sensor for import.

Do I need to be on a smart tariff to use the P1 port?
No. The data streams regardless. On a time-of-use plan, the three tariff sensors let you track day, night and peak separately.

Which Home Assistant integration do I use?
The ESPHome integration. The gateway is discovered automatically; no “P1 Monitor” or “DSMR” integration and no MQTT needed.

Can I get gas and water into the Energy dashboard too?
Not through the P1 port; the Irish telegram carries electricity only. Analog gas and water meters can be read with a Gas Meter Gateway or Water Meter Gateway; Kamstrup heat and water meters with the Kamstrup Gateway.

Can I change what the gateway reports?
Yes, completely. It runs ESPHome, so every sensor is defined in a YAML file you edit and push over the air.

Will this work on a three-phase meter?
Untested. Add L2/L3 current and sag/swell sensors to the config and let us know.

Do I need an in-home display from ESB Networks?
No, and they don’t supply one. The gateway plus Home Assistant is your in-home display.

Is my data safe?
Everything over the P1 port stays on your local network, encrypted between the gateway and Home Assistant. The meter’s own reporting to ESB Networks is unaffected and governed by GDPR and the Data Protection Act 2018.

Conclusion

ESB Networks switching on the P1 port is the biggest step forward for home energy monitoring in Ireland since the smart meter rollout began. The Smart Meter WiFi Gateway ESPHome Edition is built for exactly this kind of situation: powered by the meter, fully configurable, natively integrated with Home Assistant, and open enough that a customer could make it work for a new country before we could. Three things to get right: check your meter can be enabled, enable it in your ESB Networks account, and flash the Irish config above. If you get it running on a three-phase meter or a different meter model, share your results so the compatibility table can grow.

Last updated: 4 November 2026. Config and Irish telegram analysis: James Pelow, adapted from the Smart Gateways ESPHome firmware (2025-10-21). Tested on a single-phase ESB Networks (Sagemcom XS211) smart meter in Ireland. Published by Smart Gateways B.V.

Leave a Reply

Your email address will not be published. Required fields are marked *